List of main standards applied during laboratory tests
Applied Standards
The standards listed here are only part of what Sicom Testing may apply during the tests in laboratory.
For the execution of tests in accordance with other standards you can still contact the laboratory to verify the feasibility.
Compatibilità Elettromagnetica
- SEARCH EN 301 489-1 / 3 / 5 / 6 / 7 / 8 / 9/ 13/ 17 / 23/ 24/ 50 – EMC & ERM Common technical requirements / SRD / PMR system / DECT equipment / sistemi GSM e DCS / CB radio / Sistemi apart larga / Mobile computers UTRA / Base stations for mobile communications, repeater and ancillary equipment
- SEARCH EN 300 454-2 – Audio Connections Broadband - Essential requirements
- SEARCH EN 300 422-2 – Wireless microphones in the frequency band 25 MHz a 3 GHz - Essential requirements
- CENELEC IN 55013 – Television and radio receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement
- CENELEC IN 55020 – broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement
- CENELEC IN 55022 – Devices for information technology - Radio disturbance characteristics - Limits and methods of measurement
- CENELEC IN 55014 – Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus
- CENELEC IN 50130-4 – d Alarm systems - Part 4: Electromagnetic compatibility - Product family standard for: Immunity requirements for components of fire, intruder and social alarm | Norma / generic and / or relative / and
- CENELEC IN 61547 – Equipment for general lighting purposes - EMC immunity requirements
- CENELEC IN 61000-3-2 – Limits for harmonic current emissions (equipment with an input current <= 16 A per phase)
- CENELEC IN 61000-3-3 – Limitation of changes in voltages, voltage fluctuations and flicker in low voltage supply systems for equipment with rated current <= 16 A per phase and not subject to conditional connection
- CENELEC IN 61000-4-2 – Immunity test to electrostatic discharge
- CENELEC IN 61000-4-3 – Proof of immunity to electromagnetic fields radiated RF
- CENELEC IN 61000-4-4 – Immunity test Electrical fast transient / trains
- CENELEC IN 61000-4-5 – Try Surge immunity
- CENELEC IN 61000-4-6 – Immunity to conducted disturbances induced by RF fields
- CENELEC IN 61000-4-11 – Proof of immunity to voltage drops, short interruptions and voltage variations
- CENELEC IN 61000-6-1 - Immunity for residential, commercial and light industry
- CENELEC IN 61000-6-2 – Immunity for industrial environments
- CENELEC IN 61000-6-3 – Emissions for residential, commercial and light industry
- CENELEC IN 61000-6-4 - Emission standard for industrial environments
- CENELEC IN 61000-4-13 – Low frequency phenomena immunity
- CENELEC IN 55024 – Equipment for information technology – Immunity characteristics – Limits and methods of measurement
- CENELEC IN 55103 – audio equipment, video, audiovisual and entertainment lighting control for professional use
- CENELEC IN 60439-1 – Equipment assembled protection and maneuver for low voltage (switchboards BT)
- CENELEC IN 61326-1 - Electrical equipment for measurement, control and laboratory use - General requirements
- SEARCH EN 300 296-2 – Electromagnetic compatibility and matters relating to the radio frequency spectrum (ERM); Land Mobile Service; Radio equipment using integral antennas intended primarily for analogue speech
- SEARCH EN 301 843-1 / 2 – Marine radio equipment and services – Common technical requirements / Specific conditions for radiotelephone transmitters and receivers
- CENELEC IN 60730-1 / 2- Automatic electrical controls for household and similar purposes - General and Special rules
- IEC 62040-2 – Uninterruptible power systems (UPS) - Electromagnetic Compatibility Requirements
- CENELEC IN 50293 – traffic light systems for road use - Electromagnetic Compatibility
Sicurezza
- CENELEC IN 60950-1 – Safety Equipment requirements for information technology
- CENELEC IN 62368-1 "Audio / video equipment, Information technology and communications - part 1: Safety requirements "
- CENELEC IN 60950-22 - instrument safety requirements for information technology installed outdoors
- CENELEC IN 60335 – Safety of household and similar electrical appliances
- CENELEC IN 60065 – Audio, video and similar electronic equipment – Safety requirements
- CENELEC IN 61010 – Safety requirements for electrical equipment for measurement, control, and laboratory use
- CENELEC IN 41003 – Particular safety requirements for equipment to be connected to telecommunication networks and / or cable distribution systems
- CENELEC IN 50564 – Domestic appliances and office equipment and electrical – Measurement of energy consumption in low power
- IEC / THE EN 61960-1 - batteries and lithium batteries for portable applications - Lithium
- IEC / THE EN 62133 – Elements and storage batteries containing alkaline electrolytes or other non-acid - Safety requirements for watertight batteries, and for batteries obtained thereof, for portable applications
- CENELEC IN 50491-2 – General requirements for electronic systems for the home and the building (HBES) and automation and control systems for buildings (BINS) – Environmental conditions
- IEC / THE EN 60601-1 - Electrical safety of electromedical devices
- CENELEC IN 60745-1 – Safety of power tools Portable motor – General requirements
- THE EN 60745-2-3 – Safety of power tools, motor - Particular requirements for grinders, sanders and polishers with disk type
- IEC 60884-1 / 2 – Plugs and sockets for household and similar purposes - Requirements
- ON 60529 – Degrees of protection provided by enclosures penetration of solid bodies or liquids
- IEC 61340 – Protection of electronic devices from electrostatic phenomena
- IEC 62040-1 – Uninterruptible power systems (UPS) - General and safety requirements
- IEC 62040-3 – Uninterruptible power systems (UPS) – Method of specifying the performance and test requirements.
- ON 50556 – traffic light systems for road use - Security
- UNITED IN 12675 – traffic signal controllers – Functional safety requirements
- UL 60950-1 – Information Technology Equipment – Safety – General Requirements
mobile Phones
- SEARCH EN 301 511 – Mobile stations in the GSM 900 and DCS 1800
- SEARCH EN 301 419-1 – Requirements for accessing the mobile stations to the GSM network 900 and DCS 1800
- SEARCH EN 301 419-7 – Requirements for access to GSM mobile stations Railways Network
- 3GPP TS 51.010-1 – Specifications GSM Compliance / GPRS (EGSM, R-GSM, GSM900, 1800 and 1900 MHz)
- SEARCH EN 300 607-1 – Specifications GSM Compliance / GPRS (EGSM, R-GSM,,GSM900, 1800 and 1900 MHz)
- SEARCH EN 300 607-4 – Specifications of conformity of the SIM Application Toolkit
- 3GPP TS 34.121-1 – Specific compliance of UMTS terminals, transmission and radio reception
- SEARCH EN 301 908-1 – Harmonized Standard for IMT-2000- common requirements
- SEARCH EN 301 908-2 – Harmonized Standard for IMT-2000, BOTH FDD EU
- SEARCH EN 301 908-13 - Harmonized standard for IMT-2000, E-UTRA UE
- SEARCH EN 300 609-4 – Harmonized Standard for the GSM Repeaters – Essential requirements
- ETSI TS 102 933 – 2 - Railway Telecommunications - Parameters of tests on the receiver and rail type GSM transmitter (GSM-R)
- ETSI TS 151 010-1 – Specification Compliance mobile stations (MS)
- SEARCH EN 301 502 - Harmonized Standard for the equipment of GSM base station - Essential requirements
- SEARCH EN 301 908-11 - Harmonized Standard for IMT cellular networks – CDMA (UTRA FDD)
cordless Phones
- SEARCH EN 301 406 – Harmonized Standard for DECT
- ETSI TBR 10 – DECT Telephony Applications
- ETSI TBR 22 – Applications Generic Access Profile (GAP) DECT
Radio, WiFi e Short Range Devices
- SEARCH EN 300 433-2 – Apparatus for CB radios (CB) - Essential requirements
- SEARCH EN 300 113-2 – Land Mobile Service (VHF or UHF) - Essential requirements
- SEARCH EN 301 178-2 – portable radiotelephone equipment for the maritime mobile service operating in the VHF bands
- SEARCH EN 300 328 – ERM systems of transmission broadband band 2.4 Ghz (WiFi, Bluetooth, ZigBee, RLAN)
- SEARCH EN 300 220 – ERM short radius Devices (SRD) in the frequency band 25 MHz a 1000 MHz with power levels up to 500 mW
- SEARCH EN 300 330 – ERM short radius Devices (SRD) nella gamma di frequenze da 9 KHz a 25 MHz, inductive loop systems in the frequency range of 9 kHz to 30 MHz
- SEARCH EN 300 440 – ERM short radius Devices (SRD) nell’intervallo di frequenza da 1 GHz a 40 Ghz
- SEARCH EN 301 893 – BRAN (Broadband Radio Access Networks, access networks in RF broadband); RLAN high performance in the frequency band 5 Ghz
- SEARCH EN 301 357 – Wireless audio equipment in the band between 25 MHz e 2 000 Mhz - Essential requirements
Human exposure and SAR
- CENELEC IN 50360 – Compliance of mobile phones with the basic restrictions related to human exposure to EM fields (300 MHz – 3 Ghz)
- CENELEC IN 50385 – Compliance of radio base stations and fixed terminal stations for human exposure limits to EM fields (110 MHz – 40 Ghz)
- CENELEC IN 50371 – Compliance of low power devices to the limits of exposure to EM fields (10 MHz – 300 Ghz)
- CENELEC IN 62311 – Assessment of electronic and electrical equipment in relation to the basic limits for human exposure to electromagnetic fields (0Hz – 300Ghz)
- CENELEC IN 62209 – Human exposure to radio frequency fields from wireless communication devices handheld or mounted on the body
- CENELEC IN 50383 – Standard for the calculation and measurement of EM fields and SAR measurements of radio base stations and fixed terminal stations (110 MHz-40 GHz)
- CENELEC IN 50361 – Standard for the SAR measures in relation to human exposure to EM fields from mobile terminals (300 MHz-3 GHz)
- CENELEC IN 50566 – Product standard to demonstrate compliance with regard to electromagnetic fields from portable wireless communication devices to hold and lead to body contact, for use by the population (30 MHz — 6 Ghz)
- CENELEC IN 62479 – Evaluation of conformity of electrical and electronic apparatuses of weak power with the basic restrictions related to human exposure to electromagnetic fields (10 MHz — 300 Ghz)
- CENELEC IN 50364 – Limitation of human exposure to electromagnetic fields from devices operating in the frequency range 0 Hz — 300 Ghz, used in Electronic Article Surveillance (EAS), in radio frequency identification systems (RFID) and similar applications
- CENELEC IN 62233 – Measurement methods for electromagnetic fields of electrical household and similar apparatus with regard to human exposure
Railway equipment
- CENELEC IN 50155 – Railway applications, tramway, trolleybus and subways - Electronic equipment used on rolling stock
- CENELEC IN 50121 – Railway applications, tramway, trolleybus and metropolitan Electromagnetic Compatibility
- CENELEC IN 50153 – Railway applications, tramway, trolleybus and subways - Rolling stock - Protective measures against electrical hazards
- CENELEC IN 45545 – Applicazioni ferroviarie — Protezione al fuoco per i rotabili ferroviari
- ON 61373 – Rolling stock – Impact tests and vibration
- ON 60068 – Tests and environmental
- ON 50125 - Railway applications - Environmental conditions
- ON 60077 – Railway applications: electrical equipment for rolling stock
- SOME THOSE 11170-3 – Railway Rolling Stock Vehicles – Guidelines for fire protection of railway vehicles and guided path – Evaluation of fire behavior of materials – Limits of acceptance
Apparecchi di illuminazione
- ON / IEC 60598-1 “Luminaires Part 1: General requirements and tests”
- ON / IEC 60598-2-1 “special requirements – fixed luminaires for general use”
- ON / IEC 62493 “Evaluation of lighting equipment relatively to human exposure to electromagnetic fields”
- ON / IEC 62471 “Photobiological safety of lamps and lamp systems”
- IEC / TR 62778 "Application of IEC 62471 to the light sources and to luminaires for risk assessment by blue light "
- ON 61547 “Equipment for general lighting – EMC immunity requirements”
- ON 55015 “Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment”
- ON 62560 – LED lamps with built-in power supply for general lighting with a voltage > 50 V – Safety Specifications
- ON 62493 – Evaluation of the apparatus relatively to human exposure to electromagnetic fields lighting
- ON 62031 – LED modules for general lighting - Safety specifications
- ON 60838-2-2 – Miscellaneous lampholders - Particular requirements - Connectors for LED modules
- ON 61347-1 – of Lamp controlgear - General requirements and safety
- ON 61347-2 – of lamp power supply unit - Particular requirements for electronic transformers for incandescent lamps fed in d.c.. o in c.a.
- ON 60061 – Attacks and supports for lamps with gauges for the control and safety
- ON 13032-1 – Light and lighting – Measurement and presentation of photometric data of lamps and luminaires – Measurement and file format
Ecodesign
- Directive 2009/125 / EC “establishing a framework for the setting of requirements for the eco-design of energy-related products "
- Implementing measures for the environmentally friendly design of directional lamps, lamps, light emitting diodes and related equipment (I) n.1194/2012 edition (I) 2015/1428
- Regulation (I) 2017/1369 “establishing a framework for energy labeling and repealing Directive 2010/30 / EU”
- Implementing measures for energy labeling of directional lamps, lamps, light emitting diodes and related equipment (I) n.874/2012.
FCC and ISED
- FCC CFR Title 47, Chapter I, set off 15 B e 15 C – Radio frequency device – Unintentional and intentional radiators
- IEEE 1528 – Determination of the SAR in the human head generated by wireless communication devices
- FCC OET 65C – Conformity assessment of portable and mobile devices to the FCC limits for human exposure to RF fields
- ICES-003 — Information Technology Equipment (Including Digital Apparatus) — Limits and Methods of Measurement
- IC RSS-102 – Requirements and measurement techniques used to evaluate RF exposure compliance of radiocommunication apparatus (Category I and Category II equipment)
Boat and ship
- I'M NOT A BIG SLEEP 16315 Electric propulsion system
- I'M NOT A BIG SLEEP 25197 electrical / electronic system for the directional control, inverter and accelerator
- I'M NOT A BIG SLEEP 10240 Owner's Manual
- I'M NOT A BIG SLEEP 13297 electrical Systems – alternating current systems
- IN THAT 10133 very low voltage direct current systems
- IN THAT 8848 steering systems remotely
- IEC 60092 – 303 Transformers
- IEC61558 – 2 – 4 Isolation
- IEC 60146 Converters
- IEC 60034 Engines
- IEC 60945 Compatibilità Elettromagnetica (EMC)
Furniture
- IN THAT 12100 Safety of machinery - General principles for design - Risk assessment and risk reduction
- ON 349 Safety of machinery - Minimum gaps to avoid crushing of parts of the body
- ON 60335-1 "Safety of electrical appliances for household and similar purposes – Parte 1: General rules"
- ON 62233 "Methods of measurement for electromagnetic fields of electrical appliances for domestic use and the like with reference to human exposure"
- ON 55014-1 "Electromagnetic compatibility - Immunity requirements for household appliances, tools and similar equipment - Part 1: Issuance "
- ON 55014-2 "Electromagnetic compatibility - Immunity requirements for household appliances, tools and similar equipment - Part 2: Immunity"
- ON 61000-6-2 "Electromagnetic compatibility (EMC) - part 6-2: Generic standards - Immunity for industrial environments "
Dispositivi Medici
- ON 60601-1 “electrical equipment - Part 1: General requirements for basic safety and essential performance”
- ON 60601-1-6 “electrical equipment - Part 1: General requirements for safety - Collateral standard:Usability”
- ON 60601-1-11 "Electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral standard: Requirements for electro-medical systems and devices for home use "
- ON 60601-2-52 "Electrical equipment – Parte 2-52: Special requirements relating to basic safety and essential performance of medical beds "
- ON 60529 “Degrees of protection provided by enclosures (IP Code)”
- ON 62311 “Assessment of electronic and electrical equipment in relation to the basic limits for human exposure to electromagnetic fields (0 Hz – 300 Ghz)”
- Drafting of the risk assessment in accordance with Directive “Cars” 2006/42/EC
- IN THAT 12100 Safety of machinery - General principles for design - Risk assessment and risk reduction
- ON 349 Safety of machinery - Minimum gaps to avoid crushing of parts of the body
- ON 60601-1-2 “electrical equipment - Part 1-2: General requirements relating to basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests”
- ON 61000-3-2 "Electromagnetic compatibility (EMC) Parte 3-2: Limitations – Limits for harmonic current emissions (equipment with an input current <= 16 A per phase)"IN 61000-3-3 "Electromagnetic compatibility (EMC) Parte 3-3: Limitations – Limitation of changes in voltages, of voltage fluctuations and flicker in low voltage supply systems for equipment with rated current <= 16 A per phase and not subject to conditional connection "
- IN THAT 14971 "Medical devices – Application of risk management to medical devices "