Applied standards

Listed below are some of the standards according to which tests are performed in our laboratories.

There are many other similar standards that we can perform, for example in the field of household appliances and consumer electronics.
Another area in which we operate is that of laboratory and special equipment used, for example, in research centres.
Large equipment are tested on site, carrying the instrumentation and operating in accordance with the European guidelines.

If you want to run tests according to standards that are not in the following list, contact us and we will check if we can offer you the service anyway.

EMC

  • ETSI EN 301 489-1 / 3 / 5 / 6 / 7 / 8 / 9/ 13/ 17 / 23/ 24/ 50 – EMC & ERM common technical requirements / SRD / PMR systems / DECT equipment / GSM and DCS systems / CB radio / Broadband systems / Mobile terminals UTRA / Base stations for cellular communications, repeaters and ancillary equipment
  • ETSI EN 300 454-2 – Wideband audio links – essential requirements
  • ETSI EN 300 422-2 – Wireless microphones in the frequency band from 25 MHz to 3 GHz – essential requirements
  • CENELEC EN 55013 – Radio and television receivers and associated equipment — radio disturbance characteristics — limits and methods of measurement
  • CENELEC EN 55020 – radio and television receivers and associated equipment — immunity characteristics — limits and methods of measurement
  • CENELEC EN 55022 – Dell ’ information technology equipment — radio disturbance characteristics — limits and methods of measurement
  • CENELEC EN 55014 – Electromagnetic compatibility — Requirements for household appliances, electric tools and similar apparatus
  • CENELEC EN 50130-4 – Alarm systems — part 4: Electromagnetic compatibility — product family standard: Immunity requirements for components of fire protection systems, intruder and social alarm | Standard/generic/and that its
  • CENELEC EN 61547 – Equipment for general lighting purposes — EMC immunity requirements
  • CENELEC EN 61000-3-2 – Limits for harmonic current emissions (equipment with input current <= 16 A per phase)
  • CENELEC EN 61000-3-3 – Limitation of voltage variations, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current <= 16 A per phase and not subject to conditional connection condition
  • CENELEC EN 61000-4-2 – Electrostatic discharge immunity test
  • CENELEC EN 61000-4-3 – Radiated radiofrequency electromagnetic field immunity test
  • CENELEC EN 61000-4-4 – Electrical fast transient immunity test/train
  • CENELEC EN 61000-4-5 – Impulse immunity test
  • CENELEC EN 61000-4-6 – Immunity to conducted disturbances induced by radio-frequency fields
  • CENELEC EN 61000-4-11 – Evidence of immunity to Voltage dips, short interruptions and voltage variations
  • CENELEC EN 61000-6-1 -Immunity for residential, ’ commercial and light industry
  • CENELEC EN 61000-6-2 – Immunity for industrial environments
  • CENELEC EN 61000-6-3 – Emissions for residential, ’ commercial and light industry
  • CENELEC EN 61000-6-4 – Emissions for industrial environments
  • CENELEC EN 61000-4-13 – Low frequency phenomena immunity
  • CENELEC EN 55024 – Dell ’ information technology equipment – Immunity characteristics – Limits and methods of measurement
  • CENELEC EN 55103 – Audio units, video, audio-visual and entertainment lighting control for professional use
  • CENELEC EN 60439-1 – Low-voltage switchgear and protective equipment assembled (LV switchboards)
  • CENELEC EN 61326-1 – Electrical equipment for measurement, control and laboratory use – general requirements
  • ETSI EN 300 296-2 – Electromagnetic compatibility and radio spectrum matters (ERM); Land mobile service; Radio equipment using antennas intended primarily for analogue voice communications
  • ETSI EN 301 843-1 / 2 – Marine radio equipment and services – Common technical requirements / Specific conditions for radiotelephone transmitters and receivers
  • CENELEC EN 60730-1 / 2- Automatic electrical controls for household and similar use – general rules and details
  • IEC 62040-2 – Uninterruptible power systems (UPS) – Electromagnetic compatibility requirements
  • CENELEC EN 50293 – Traffic for road traffic systems – electromagnetic compatibility

Safety

  • CENELEC EN 60950-1 – Safety requirement of information technology equipment of ’
  • CENELEC EN 60950-22 – Safety requirements for information technology equipment installed all dell ’ open ’
  • CENELEC EN 60335 – Safety of household and similar electrical appliances
  • CENELEC EN 60065 – Audio, video and similar electronic apparatus – Safety requirements
  • CENELEC EN 61010 – Safety requirements for electrical equipment for measurement, control and laboratory use
  • CENELEC EN 41003 – Particular safety requirements for equipment to be connected to telecommunication networks and/or cable distribution systems
  • CENELEC EN 50564 – Domestic appliances and office equipment and electric – Measurement of power consumption in low-power
  • IEC / CEI EN 61960-1 – Batteries and lithium batteries for portable applications – lithium-ion batteries
  • IEC / CEI EN 62133 – Elements and batteries containing alkaline or other non-acid electrolytes – safety requirements for accumulators ponds, and for which they have obtained, for portable applications
  • CENELEC EN 50491-2 – General requirements for electronic systems for the home and building (HBES) and building automation and control systems (BACS) – Environmental conditions
  • IEC / CEI EN 60601-1 – Electrical safety of medical electrical equipment
  • CENELEC EN 60745-1 – Security power tools portable power – General requirements
  • CEI EN 60745-2-3 – Motor power tools safety – particular requirements for Sanders, grinding and polishing machines disk type
  • IEC 60884-1 / 2 – Plugs and socket-outlets for household and similar purposes – prescriptions
  • EN 60529 – Degrees of protection provided by enclosures penetration of solids or liquids
  • IEC 61340 – Protection of electronic devices from electrostatic phenomena
  • IEC 62040-1 – Uninterruptible power systems (UPS) – General and safety requirements
  • IEC 62040-3 – Uninterruptible power systems (UPS) – Methods of specifying performance and test requirements.
  • EN 50556 – Traffic for road traffic systems – security
  • UNI EN 12675 – Traffic controllers – Functional safety requirements
  • UL 60950-1 – Information Technology Equipment – Safety – General Requirements

Mobile phones

  • ETSI EN 301 511 – Mobile stations in the GSM band 900 and DCS 1800
  • ETSI EN 301 419-1 – ’ requirements for mobile stations access to GSM network 900 and DCS 1800
  • ETSI EN 301 419-7 – Requirements for mobile stations access to the network ’ Railways GSM
  • 3GPP TS 51.010-1 – Compliance specification GSM/GPRS (EGSM, R-GSM, GSM900, 1800 and 1900 MHz)
  • ETSI EN 300 607-1 – Compliance specification GSM/GPRS (EGSM, R-GSM,,GSM900, 1800 and 1900 MHz)
  • ETSI EN 300 607-4 – Compliance of the SIM Application Toolkit
  • 3GPP TS 34.121-1 – Compliance of UMTS terminals, radio transmission and reception
  • ETSI EN 301 908-1 – Harmonized en for IMT-2000- Common requirements
  • ETSI EN 301 908-2 – Harmonized en for IMT-2000, UTRA FDD UE
  • ETSI EN 301 908-13 – Harmonized en for IMT-2000, E-UTRA EU
  • ETSI EN 300 609-4 – Harmonised standard for GSM repeaters – Essential requirements
  • ETSI TS 102 933 – 2 – Railway Telecommunications – GSM transmitter and receiver testing parameters of rail type (GSM-R)
  • ETSI TS 151 010-1 – Compliance specification mobile stations (MS)
  • ETSI EN 301 502 – Harmonised Standard for GSM base station equipment ’ – essential requirements
  • ETSI EN 301 908-11 – Harmonised Standards for cellular networks IMT – CDMA (UTRA FDD)

Cordless phones

  • ETSI EN 301 406 – Harmonised standard for DECT
  • ETSI TBR 10 – DECT telephony applications
  • ETSI TBR 22 – Generic Access Profile Applications (GAP) DECT

Radio, WiFi and Short Range Devices

  • ETSI EN 300 433-2 – Citizen band radio equipment (CB) – Essential requirements
  • ETSI EN 300 113-2 – Land mobile service (VHF or UHF) – Essential requirements
  • ETSI EN 301 178-2 – Portable radiotelephone equipment for the maritime mobile service operating in VHF bands
  • ETSI EN 300 328 – ERM-band wideband transmission systems 2.4 GHz (WiFi, Bluetooth, ZigBee, RLAN)
  • ETSI EN 300 220 – ERM short-range Devices (SRD) in the frequency band from 25 MHz to 1000 MHz with power levels up to 500 MW
  • ETSI EN 300 330 – ERM short-range Devices (SRD) in the frequency range from 9 KHz to 25 MHz, inductive loop systems in the frequency range from 9KHz to 30 MHz
  • ETSI EN 300 440 – ERM short-range Devices (SRD) in the frequency range ’ 1 GHz 40 GHz
  • ETSI EN 301 893 – BRAN (Broadband Radio Access Networks, broadband radio access networks); High performance RLAN in the frequency band 5 GHz
  • ETSI EN 301 357 – Wireless audio equipment in the band between 25 MHz and 2 000 MHz – essential requirements

Human exposure and SAR

  • CENELEC EN 50360 – Compliance of mobile phones with the basic restrictions related to human exposure to EM fields ’ (300 MHz – 3 GHz)
  • CENELEC EN 50385 – Compliance of radio base stations and fixed terminal stations the limits for all ’ human exposure to EM fields (110 MHz – 40 GHz)
  • CENELEC EN 50371 – Light duty equipment readiness to exposure to EM fields (10 MHz – 300 GHz)
  • CENELEC EN 62311 – Assessment of electronic and electrical equipment in connection with the basic restrictions for the ’ human exposure to electromagnetic fields (0Hz – 300GHz)
  • CENELEC EN 62209 – Human exposure to radio frequency fields from hand-held wireless communication devices or mounted on the body
  • CENELEC EN 50383 – Standard for the calculation and measurement of EM fields and for SAR measures for base stations and fixed terminal stations (110 MHz-40 GHz)
  • CENELEC EN 50361 – Standard for SAR measures in regard to the ’ human exposure to EM fields from mobile terminals (300 MHz-3 GHz)
  • CENELEC EN 50566 – Product standard to demonstrate compliance with regard to electromagnetic fields from devices, portable wireless communication to hold and to take body contact, for use by the population (30 MHz — 6 GHz)
  • CENELEC EN 62479 – Conformity assessment of electrical and electronic equipment of low power basic restrictions related to human exposure to electromagnetic fields ’ (10 MHz — 300 GHz)
  • CENELEC EN 50364 – ’ limitation of human exposure to electromagnetic fields from devices operating in the frequency range 0 Hz — 300 GHz, used in electronic article surveillance (EAS), in radio frequency identification (RFID) and similar applications
  • CENELEC EN 62233 – Measurement methods for electromagnetic fields of household appliances and similars with reference to ’ human exposure

Railway

  • CENELEC EN 50155 – Railway applications, street cars, trolley bus applications — electronic equipment used on rolling stock
  • CENELEC EN 50121 – Railway applications, street cars, trolleybuses and subways electromagnetic compatibility
  • CENELEC EN 50153 – Railway applications, street cars, trolleybuses and subways – rolling stock – protection against hazards of electrical origin
  • CENELEC EN 45545 – Railway applications — fire protection for railway rolling stock
  • EN 61373 – Rolling stock – Shock and vibration tests d ’
  • EN 60068 – And environmental tests
  • EN 50125 – Railway applications – environmental conditions
  • EN 60077 – Railway applications: electrical equipment for rolling stock
  • UNI CEI 11170-3 – Rail vehicles – Guidelines for fire protection of rail vehicles and via led – Evaluation of fire resistance of materials – Acceptable limits

Lighting fixtures

  • CENELEC EN 55015 – Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
  • CENELEC EN 62560 – Ballasted LED lamps for general lighting with tension > 50 In – Safety specifications
  • CENELEC EN 62493 – Assessment of ’ relatively lighting equipment all ’ human exposure to electromagnetic fields
  • CENELEC EN 62031 – LED lighting modules General — safety specifications
  • CENELEC EN 60838-2-2 – Heterogeneous lampholders — particular requirements — connectors for LED modules
  • CENELEC EN 61347-1 – Lamp power supply unit — General and safety requirements
  • CENELEC EN 61347-2 – Lamp power supply unit — particular requirements for electronic transformers for filament lamps fed into c, c. or c. to.
  • CENELEC EN 60598-1 – Lighting equipment — General requirements and tests
  • CENELEC EN 60598-2 – Lighting equipment — particular requirements — Luminaires for general use
  • CENELEC EN 60061 – Attacks and holders for light bulbs with gauges for the control of interchangeability and safety ’
  • CENELEC EN 62471 – Photobiological safety of lamps and lamp systems
  • EN 13032-1 – Light and lighting – Measurement and presentation of photometric data of lamps and luminaires – Measurement and file format

FCC e ISED

  • FCC CFR Titolo 47, Chapter I, parti 15 B e 15 C – Radio frequency device – Unintentional and intentional radiators
  • IEEE 1528 – Determination of SAR in human head generated by wireless communications devices
  • FCC OET 65 – Conformity assessment of mobile and portable devices with FCC limits for human exposure to RF fields
  • ICES-003 — Information Technology Equipment (Including Digital Apparatus) — Limits and Methods of Measurement
  • IC RSS-102 – Requirements and measurement techniques used to evaluate RF exposure compliance of radiocommunication apparatus (Category I and Category II equipment)

Acceptance of network operators

  • Test requirements for end user systems approval
  • RF radiated power measurements and receiver performance

Field test

  • GSM association PRD DG. 11 – Guidelines for field trials

Need a quotation from Sicom? Our service begins here.